Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "O2k signals and output"

From Bioblast
(No difference)

Revision as of 14:11, 28 July 2015

Signal of the O2k-Core and add-on modules

Three channel types are available in the O2k-MultiSensor system:

  1. O2 channel with electric current (ampere [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The O2k-Core supports not only the O2 channel, but also the channel types 2 and 3 for the add-on modules.
  2. Amp channel: The amperometric channel of the O2k, has electric current (ampere [Amp]) as the primary signal, which is converted to a voltage (volt [V]) as the raw signal. The Amp-Channel is used with the O2k-Fluo LED2-Module and the O2k-NO Amp-Module.
  3. pX channel with electric potential (volt [V]) as the primary and raw signal (BNC plug for the ion sensitive electrode, ISE; and separate plug for the pX reference electrode, Ref).


Additional channel types are available in the NextGen-O2k:

4. Spectrophotometric channel.
5. Dual-fluo channel.


Output

The 'output' of a channel is the finally important infomation, which may be summarized in a data base. Three types of output can be derived from the signal of the O2k channels:

A: Concentration (e.g. O2; Ca2+).
B: Flow, flux, rate (e.g. O2 consumption; H2O2 production).
C: Force, potential (e.g. TMRM and Safranin for mt-membrane potential; redox potential from cytochrome or NADH redox states).


1. O2 channel - O2k-Core: Output type A and B.
2a. Amp channel - O2k-Fluo LED2-Module: The focus of the output depends on the specific fluorophore. Output type A, B, or C, or any combination may relate to the primary level of interest.
2b. Amp channel - O2k-NO Amp-Module: Output type A and B.
3a. pX channel - O2k-TPP+ ISE-Module: Output type C.
3b. pX channel - O2k-pH ISE-Module: Output type A and B.
4. Spectrophotometric channel - NextGen-O2k: Output type D (three plots for redox states of cytochromes aa3, b, and c.
5. Dual-fluo channel - NextGen-O2k: Plots of two selected wavelengths can be selected for simultaneous recording. Output type E1, E2, .. depends on the fluorophore.