== O2k-Series ==
== O2k-Series ==
The Oxygraph-2k is continuously evolving. While all O2k instruments have the same high standard for measuring respiration, there are differences in regard to:
The Oxygraph-2k is continuously evolving. While all O2k instruments have the same high standard for measuring respiration, there are differences with respect to:
* Type of [[Catalogue O2k-Stoppers|stoppers]] and [[O2k-Chamber Holder|chamber holders]] used
* Type of [[Catalogue O2k-Stoppers|stoppers]] and [[O2k-Chamber Holder|chamber holders]] used
* Type of [[OroboPOS-Connector]]
* Type of [[OroboPOS-Connector]]
Line 24: Line 24:


Therefore it may be necessary to identify the '''Series''' of your oxygraph.
Therefore it may be necessary to identify the '''Series''' of your oxygraph.
The series is specified as the first character of the serial number of the Oxygraph-2k, shown on the label on the rear of the O2k-Main Unit [[MiPNet12.06]].Β  A serial number B-xxxx or C-xxxx denotes O2k-Series B or C, while D-xxxx denotes an O2k-Series D.
The series is specified as the first character of the serial number of the O2k, shown on the label on the rear of the O2k-Main Unit [[MiPNet12.06]].Β  A serial number B-xxxx or C-xxxx denotes O2k-Series B or C, while D-xxxx denotes an O2k-Series D.
With DatLab running on-line connected to the O2k, the serial number of the currently connected Oxygraph-2k is displayed:
With DatLab running on-line connected to the O2k, the serial number of the currently connected Oxygraph-2k is displayed:
* in the right corner of the status line, besides the DatLab version number (bottom).
* in the right corner of the status line, besides the DatLab version number (bottom).

Revision as of 10:54, 5 March 2012

                



O2k-Main Unit

O2k-Catalogue

Description The O2k-Main Unit is a component of the O2k-Core. The O2k-Main Unit consists of functionally defined, integral elements, the (O2k-Main Basic, O2k-Peltier Temperature Control, two O2k-Electromagnetic Stirrer Control units, two O2k-Amperometric OroboPOS Channels, O2k-Barometric Pressure Transducer), which cannot be obtained separately.
Product ID 20000
Type O2k-Core, Catalogue
Link O2k-Core
Image

The O2k-Main Unit consists of

These are integral elements, not separately available.

The query description has an empty condition.


O2k-Series

The Oxygraph-2k is continuously evolving. While all O2k instruments have the same high standard for measuring respiration, there are differences with respect to:

Therefore it may be necessary to identify the Series of your oxygraph. The series is specified as the first character of the serial number of the O2k, shown on the label on the rear of the O2k-Main Unit MiPNet12.06. A serial number B-xxxx or C-xxxx denotes O2k-Series B or C, while D-xxxx denotes an O2k-Series D. With DatLab running on-line connected to the O2k, the serial number of the currently connected Oxygraph-2k is displayed:

  • in the right corner of the status line, besides the DatLab version number (bottom).
  • in the window caption of the O2k-Control window [F7].

A more detailed description how to determine the Series of an O2k, including pictures is included in H MiPNet15.05 NO-Manual.