O2k-Fluo LED2-Module: Difference between revisions

From Bioblast
No edit summary
No edit summary
Line 7: Line 7:
|product type=MultiSensor, Accessory, DatLab, Stopper, Workshop
|product type=MultiSensor, Accessory, DatLab, Stopper, Workshop
}}
}}
==Referenes==
==References==


*[[Hickey 2011 JCPB|Hickey AJ, Renshaw GM, Speers-Roesch B, Richards JG, Wang Y, Farrell AP, Brauner CJ (2011) A radical approach to beating hypoxia: depressed free radical release from heart fibres of the hypoxia-tolerant epaulette shark (Hemiscyllum ocellatum). J. Comp. Physiol. B.[Epub ahead of print].]]
*[[Hickey 2011 JCPB|Hickey AJ, Renshaw GM, Speers-Roesch B, Richards JG, Wang Y, Farrell AP, Brauner CJ (2011) A radical approach to beating hypoxia: depressed free radical release from heart fibres of the hypoxia-tolerant epaulette shark (Hemiscyllum ocellatum). J. Comp. Physiol. B.[Epub ahead of print].]]
*[[Fasching 2011 Abstract Berlin|Fasching M, Harrison DK, Tretter L, Gnaiger E (2011) Combination of high-resolution respirometry and fluorimetry for continuous monitoring of hydrogen peroxide production by mitochondria with resolution in the nanomolar range. Abstract Berlin]].  
*[[Fasching 2011 Abstract Berlin|Fasching M, Harrison DK, Tretter L, Gnaiger E (2011) Combination of high-resolution respirometry and fluorimetry for continuous monitoring of hydrogen peroxide production by mitochondria with resolution in the nanomolar range. Abstract Berlin]].  
*[[Sumbalova 2011 Abstract Kagoshima|Sumbalova Z, Harrison DK, Gradl P, Fasching M, Gnaiger E (2011) Mitochondrial membrane potential, coupling control, H2O2 production, and the upper limit of mitochondrial performance. Abstract Kagoshima]].
*[[Sumbalova 2011 Abstract Kagoshima|Sumbalova Z, Harrison DK, Gradl P, Fasching M, Gnaiger E (2011) Mitochondrial membrane potential, coupling control, H2O2 production, and the upper limit of mitochondrial performance. Abstract Kagoshima]].

Revision as of 15:04, 5 November 2011

                



O2k-Fluo LED2-Module

O2k-Catalogue

Description The Fluorescence O2k-MultiSensor Module is a modular extension of the Oxygraph-2k (O2k-MultiSensor System), adding a new dimension to HRR. Optical probes are inserted through the front window of the O2k-glass chamber, for measurement of hydrogen peroxide production (Amplex red), ATP production (Mg green), mt-membrane potential (Safranin), Ca2+ (Ca green), and numerous other applications open for O2k-user innovation. The Fluorescence O2k-Module consists of four optical probes (green or blue excitation), optical filters, front fixation of the optical probes to the glass windows of the O2k-chamber, two [PEEK stoppers] (with single central titration port), electronic control of light intensity, data input into the O2k-MultiSensor system, and the new DatLab 5 software.

The Fluorescence O2k-Module can be used with the O2k Series D and E, as an add-on to the MultiSensor system. Upgrading O2k Series A to C can also be achieved.

The first series of the Fluorescence O2k-MultiSensor Module will be completed by beginning of April 2012, and will be delivered in April 2012, for orders received by end of January 2012. We will offer a 2-days O2k-Fluorimetry Workshop in March 2012 in Innsbruck, Austria.

Product ID
Type MultiSensor, Accessory"Accessory" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property., DatLab"DatLab" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property., Stopper, Workshop"Workshop" is not in the list (O2k, O2k-Module, O2k-Core, O2k-Fluorometer, O2k-Main Unit, O2k-Assembly Kit, OroboPOS, OroboPOS-Service Kit, ISS, TIP2k, ...) of allowed values for the "Product type" property.
Link
Image

References