Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "MiPNet17.03 Shredder vs Fibers"

From Bioblast
Line 1: Line 1:
{{Publication
{{Publication
|title=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E. Mitochondrial respiration in permeabilized fibres versus homogenate from mouse myocardium. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03.
|title=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E (2012) Mitochondrial respiration in permeabilized fibres versus homogenate from mouse myocardium. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03.
|info=[http://oroboros.at/?Shredder_vs_Fibres MiPNet17.03 Open Access]
|info=[http://oroboros.at/?Shredder_vs_Fibres MiPNet17.03 Open Access]
|authors=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E
|authors=Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E
|year=*
|year=2012
|journal=Mitochondr Physiol Network
|journal=Mitochondr Physiol Network
|abstract=In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver.
|abstract=In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver.
Line 12: Line 12:
{{Labeling
{{Labeling
|instruments=Oxygraph-2k, Protocol, MiPNet-Publication
|instruments=Oxygraph-2k, Protocol, MiPNet-Publication
|organism=Fish
|tissues=Cardiac muscle, Hepatocyte; Liver
|preparations=Homogenate
|preparations=Homogenate
|couplingstates=LEAK, OXPHOS, ETS
|couplingstates=LEAK, OXPHOS, ETS

Revision as of 06:29, 11 January 2013

Publications in the MiPMap
Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E (2012) Mitochondrial respiration in permeabilized fibres versus homogenate from mouse myocardium. An application study with the PBI-Shredder. Mitochondr Physiol Network 17.03.

Β» MiPNet17.03 Open Access

Doerrier C, Draxl A, Wiethuechter A, Eigentler A, Gnaiger E (2012) Mitochondr Physiol Network

Abstract: In the present study we compared mitochondrial function of permeabilized fibres and homogenate of heart muscle of mice. In addition, respiration of trout heart homogenate preparations were compared with permeabilized fibres, and the PBI-Shredder was successfully tested with preparation of trout liver. β€’ Keywords: Tissue homogenate, shredder

β€’ O2k-Network Lab: AT_Innsbruck_OROBOROS, AT_Innsbruck_Gnaiger E, AT Innsbruck MitoCom


Labels:


Organism: Fish"Fish" is not in the list (Human, Pig, Mouse, Rat, Guinea pig, Bovines, Horse, Dog, Rabbit, Cat, ...) of allowed values for the "Mammal and model" property.  Tissue;cell: Cardiac muscle"Cardiac muscle" is not in the list (Heart, Skeletal muscle, Nervous system, Liver, Kidney, Lung;gill, Islet cell;pancreas;thymus, Endothelial;epithelial;mesothelial cell, Blood cells, Fat, ...) of allowed values for the "Tissue and cell" property., Hepatocyte; Liver"Hepatocyte; Liver" is not in the list (Heart, Skeletal muscle, Nervous system, Liver, Kidney, Lung;gill, Islet cell;pancreas;thymus, Endothelial;epithelial;mesothelial cell, Blood cells, Fat, ...) of allowed values for the "Tissue and cell" property.  Preparation: Homogenate 


Coupling state: LEAK, OXPHOS, ETS"ETS" is not in the list (LEAK, ROUTINE, OXPHOS, ET) of allowed values for the "Coupling states" property. 

HRR: Oxygraph-2k, Protocol"Protocol" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property., MiPNet-Publication"MiPNet-Publication" is not in the list (Oxygraph-2k, TIP2k, O2k-Fluorometer, pH, NO, TPP, Ca, O2k-Spectrophotometer, O2k-Manual, O2k-Protocol, ...) of allowed values for the "Instrument and method" property. 

mt-Preparation 

  • First on-line version: 2012-05-14.