Difference between revisions of "Layout for DatLab graphs"
From Bioblast
Line 1: | Line 1: | ||
{{MitoPedia | {{MitoPedia | ||
|description=A '''Layout''' in [[DatLab]] is a predefined selection of [[ | |description=A '''Layout''' in [[DatLab]] is a predefined selection of [[plot]]s to be displayed at specific [[scaling]]s and in a specific order. Any defined graph layout can be selected from the Layout menu for defining initial settings for the plots [Ctrl+F6] and scaling [F6]. A layout can be modified and saved under a specific name. In typical standard DatLab graph layouts plots are shown for the left chamber in Graph 1 (top), and for the right chamber in Graph 2 (below). During data acquisition, a 30 min time range is frequently used and adjusted to 1 h during the experiment [F6]. | ||
|info=[[MiPNet19.18C DatLab Guide]] | |info=[[MiPNet19.18C DatLab Guide]] | ||
}} | }} | ||
Line 8: | Line 8: | ||
__TOC__ | __TOC__ | ||
== | == Reference Layouts: O2k-Core == | ||
Version: DatLab 7 | Version: DatLab 7 | ||
:::: | :::: 01 Calibration show Temp | ||
:::: 02 Calibration - Background | |||
:::: 03 Background high O2 | |||
:::: ---- | :::: ---- | ||
:::: | :::: 04a Flux per volume | ||
:::: | :::: 04b Flux per volume overlay | ||
:::: ---- | :::: ---- | ||
:::: | :::: 05a Specific flux | ||
:::: | :::: 05b Specific flux overlay | ||
:::: | :::: 06a Specific flux high O2 | ||
:::: | :::: 06b Specific flux high O2 overlay | ||
:::: ---- | :::: ---- | ||
:::: | :::: 07a Flux Control Ratios | ||
:::: | :::: 07b Flux Control Ratios overlay | ||
=== | === 01 Calibration show Temp === | ||
::: '''General information''' | ::: '''General information''' | ||
:::: Layouts 1 ff. are considered for O2k-Core applications. | :::: Layouts 1 ff. are considered for O2k-Core applications. | ||
Line 46: | Line 40: | ||
::::» O2k-Manual: [[MiPNet19.18A_O2k-Start]] | ::::» O2k-Manual: [[MiPNet19.18A_O2k-Start]] | ||
== Reference Layouts: O2 & Amp == | |||
Version: DatLab 7 | |||
:::: 01 Amp Amperometric_Raw signal | |||
:::: 02 Amp Amperometric_Calibrated | |||
== Reference Layouts: O2 & pX == | |||
Version: DatLab 7 | |||
:::: 01 Potentiometric | |||
:::: ---- | |||
:::: 02a TPP_calibration | |||
:::: 02b TPP_with_O2flux | |||
:::: 02c TPP_calibrated_with_O2flux | |||
== Reference Layouts: Other == | |||
Version: DatLab 7 | |||
:::: O2 raw signal |
Revision as of 16:17, 22 July 2016
Description
A Layout in DatLab is a predefined selection of plots to be displayed at specific scalings and in a specific order. Any defined graph layout can be selected from the Layout menu for defining initial settings for the plots [Ctrl+F6] and scaling [F6]. A layout can be modified and saved under a specific name. In typical standard DatLab graph layouts plots are shown for the left chamber in Graph 1 (top), and for the right chamber in Graph 2 (below). During data acquisition, a 30 min time range is frequently used and adjusted to 1 h during the experiment [F6].
Reference: MiPNet19.18C DatLab Guide
MitoPedia O2k and high-resolution respirometry:
DatLab
Reference Layouts: O2k-Core
Version: DatLab 7
- 01 Calibration show Temp
- 02 Calibration - Background
- 03 Background high O2
- ----
- 04a Flux per volume
- 04b Flux per volume overlay
- ----
- 05a Specific flux
- 05b Specific flux overlay
- 06a Specific flux high O2
- 06b Specific flux high O2 overlay
- ----
- 07a Flux Control Ratios
- 07b Flux Control Ratios overlay
01 Calibration show Temp
- General information
- Layouts 1 ff. are considered for O2k-Core applications.
- Layouts Amp* or pX* are selected for O2k-MultiSensor applications.
- General information
- 1 Calibration show temp shows O2 concentration and the negative slope in Graph 1 and 2, and temperature and Peltier power in Graph 3: This is the default layout used after switching on the O2k.
- Graph 1 & 2: O2 concentration (blue lines, left Y-axis) and O2 slope neg. (uncorrected; red lines, right Y-axis) are displayed, in the top graph for the left chamber (A), and below for the right chamber (B).
- Graph 3: The third graph (bottom) shows the block temperature on the left Y axis (red) and the Peltier power on the right Y axis (green). Only when both temperature and Peltier power are constant, the chambers have reached thermal equilibrium.
- During this phase a stirrer test can be performed [F9].
- The next step is to observe equilibration of the oxygen signal with a defined gas phase above the stirred aqueous phase ('open') chamber; usually with air as the first step to perform an oxygen sensor calibration.
- 1 Calibration show temp shows O2 concentration and the negative slope in Graph 1 and 2, and temperature and Peltier power in Graph 3: This is the default layout used after switching on the O2k.
- » O2k-Manual: MiPNet19.18A_O2k-Start
Reference Layouts: O2 & Amp
Version: DatLab 7
- 01 Amp Amperometric_Raw signal
- 02 Amp Amperometric_Calibrated
Reference Layouts: O2 & pX
Version: DatLab 7
- 01 Potentiometric
- ----
- 02a TPP_calibration
- 02b TPP_with_O2flux
- 02c TPP_calibrated_with_O2flux
Reference Layouts: Other
Version: DatLab 7
- O2 raw signal