:::: The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al<ref>Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca<sup>2+</sup>-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.</ref>. The limit of detection is less than 10 nM in Ca<sup>2+</sup> buffered calibration solutions. The main difficulty in establishing reliable Ca<sup>2+</sup> measurements is not the Ca<sup>2+</sup> sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: [[O2k-TPP+ ISE-Module#Calcium_electrode]].
:::: The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al<ref>Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca<sup>2+</sup>-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.</ref>. The limit of detection is less than 10 nM in Ca<sup>2+</sup> buffered calibration solutions. The main difficulty in establishing reliable Ca<sup>2+</sup> measurements is not the Ca<sup>2+</sup> sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: [[O2k-TPP+ ISE-Module#Calcium_electrode]].
== References ==
<references/>





Revision as of 14:50, 2 November 2020

                



ISE-Ca2+ Membranes

O2k-Catalogue

Description
Ca2+ membranes.jpg
ISE-Ca2+ Membranes: PVC, 4 mm diameter, box of 5 membranes.

To be used with the O2k-TPP+ ISE-Module.

Product ID
Type
Link ISE Manual, O2k-TPP+ ISE-Module#Calcium_electrode, O2k-spares
Image


Technical support

The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al[1]. The limit of detection is less than 10 nM in Ca2+ buffered calibration solutions. The main difficulty in establishing reliable Ca2+ measurements is not the Ca2+ sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: O2k-TPP+ ISE-Module#Calcium_electrode.

References

  1. ↑ Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca2+-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.