Cookies help us deliver our services. By using our services, you agree to our use of cookies. More information

Difference between revisions of "ISE-Ca2+ Membranes"

From Bioblast
Line 1: Line 1:
{{Product
{{Product
|description='''ISE-Ca2+ Membranes''': PVC, 4 mm diameter, box of 5 membranes.
|description=[[Image:Ca2+ membranes.jpg|right|180px]]'''ISE-Ca2+ Membranes''': PVC, 4 mm diameter, box of 5 membranes.
To be used with the [[O2k-TPP+ ISE-Module]]. The ISE-Ca2+ Membranes have to be ordered separately.
To be used with the [[O2k-TPP+ ISE-Module]]. Β 
|product id=42280-01
|product type=O2k, MultiSensor
|info= [[MiPNet15.03 O2k-MultiSensor-ISE|ISE Manual]], [[O2k-TPP+ ISE-Module#Calcium_electrode]], [[ISE-Consumables Spares Set|O2k-spares]]
|info= [[MiPNet15.03 O2k-MultiSensor-ISE|ISE Manual]], [[O2k-TPP+ ISE-Module#Calcium_electrode]], [[ISE-Consumables Spares Set|O2k-spares]]
|product image=[[Image:Ca2+ membranes.jpg|right|180px]]
}}
}}


The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al<ref>Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca<sup>2+</sup>-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.</ref>. The limit of detection is less than 10 nM in Ca<sup>2+</sup> buffered calibration solutions. The main difficulty in establishing reliable Ca<sup>2+</sup> measurements is not the Ca<sup>2+</sup> sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: [[O2k-TPP+ ISE-Module#Calcium_electrode]].
== Technical support ==
:::: The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al<ref>Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca<sup>2+</sup>-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.</ref>. The limit of detection is less than 10 nM in Ca<sup>2+</sup> buffered calibration solutions. The main difficulty in establishing reliable Ca<sup>2+</sup> measurements is not the Ca<sup>2+</sup> sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: [[O2k-TPP+ ISE-Module#Calcium_electrode]].


== References ==
Β 
<references/>
{{MitoPedia O2k and high-resolution respirometry
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
}}

Revision as of 14:49, 2 November 2020

                



ISE-Ca2+ Membranes

O2k-Catalogue

Description
Ca2+ membranes.jpg
ISE-Ca2+ Membranes: PVC, 4 mm diameter, box of 5 membranes.

To be used with the O2k-TPP+ ISE-Module.

Product ID
Type
Link ISE Manual, O2k-TPP+ ISE-Module#Calcium_electrode, O2k-spares
Image


Technical support

The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al[1]. The limit of detection is less than 10 nM in Ca2+ buffered calibration solutions. The main difficulty in establishing reliable Ca2+ measurements is not the Ca2+ sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: O2k-TPP+ ISE-Module#Calcium_electrode.


MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry 

  1. ↑ Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca2+-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.