Difference between revisions of "ISE-Ca2+ Membranes"
From Bioblast
Beno Marija (talk | contribs) |
Beno Marija (talk | contribs) |
||
Line 1: | Line 1: | ||
{{Product | {{Product | ||
|description='''ISE-Ca2+ Membranes''': PVC, 4 mm diameter, box of 5 membranes. | |description=[[Image:Ca2+ membranes.jpg|right|180px]]'''ISE-Ca2+ Membranes''': PVC, 4 mm diameter, box of 5 membranes. | ||
To be used with the [[O2k-TPP+ ISE-Module]]. | To be used with the [[O2k-TPP+ ISE-Module]]. Β | ||
|info= [[MiPNet15.03 O2k-MultiSensor-ISE|ISE Manual]], [[O2k-TPP+ ISE-Module#Calcium_electrode]], [[ISE-Consumables Spares Set|O2k-spares]] | |info= [[MiPNet15.03 O2k-MultiSensor-ISE|ISE Manual]], [[O2k-TPP+ ISE-Module#Calcium_electrode]], [[ISE-Consumables Spares Set|O2k-spares]] | ||
}} | }} | ||
The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al<ref>Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca<sup>2+</sup>-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.</ref>. The limit of detection is less than 10 nM in Ca<sup>2+</sup> buffered calibration solutions. The main difficulty in establishing reliable Ca<sup>2+</sup> measurements is not the Ca<sup>2+</sup> sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: [[O2k-TPP+ ISE-Module#Calcium_electrode]]. | == Technical support == | ||
:::: The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al<ref>Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca<sup>2+</sup>-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.</ref>. The limit of detection is less than 10 nM in Ca<sup>2+</sup> buffered calibration solutions. The main difficulty in establishing reliable Ca<sup>2+</sup> measurements is not the Ca<sup>2+</sup> sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: [[O2k-TPP+ ISE-Module#Calcium_electrode]]. | |||
= | Β | ||
{{MitoPedia O2k and high-resolution respirometry | |||
|mitopedia O2k and high-resolution respirometry=O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry | |||
}} |
Revision as of 14:49, 2 November 2020
ISE-Ca2+ Membranes
Description | ISE-Ca2+ Membranes: PVC, 4 mm diameter, box of 5 membranes.
To be used with the O2k-TPP+ ISE-Module. |
---|---|
Product ID | |
Type | |
Link | ISE Manual, O2k-TPP+ ISE-Module#Calcium_electrode, O2k-spares |
Image |
Technical support
- The composition of the ISE-Ca2+ Membranes is similar to the one described by Simon et al[1]. The limit of detection is less than 10 nM in Ca2+ buffered calibration solutions. The main difficulty in establishing reliable Ca2+ measurements is not the Ca2+ sensitive membrane but the methodology of its application in a medium simulating intracellular conditions. Further details: O2k-TPP+ ISE-Module#Calcium_electrode.
MitoPedia O2k and high-resolution respirometry: O2k hardware, O2k-Open Support, O2k-Respirometry, O2k-FluoRespirometry
- β Schefer U, Ammann D, Pretsch E, Oesch U, Simon W (1986) Neutral carrier based Ca2+-selective electrode with detection limit in the sub-nanomolar range. Analyt Chem 58:2282-5.